shopping basket
basket
item - £0.00

You have no items in your shopping basket.

Subtotal
£0.00

Prestige Low Surface Temperature Towel Warmer Chrome MOA

More Views

Prestige Low Surface Temperature Towel Warmer Straight Chrome

Be the first to review this product

Quick Code: # 14320
£157.00 ex. VAT £188.40 incl. VAT

* Required Fields

Availability: In stock

Warranty: 15 Years
Delivery: 48 Hours
FREE Delivery
  • Ideal for care homes or where low surface temperatures are essential
  • Choice of left or right hand side element installation
  • Thermostatic element sizes: 200W, 400W and 800W
  • Low standby power consumption
  • Double overheating protection
  • IPX5 suitable for zone two bathrooms

Details

    maximum surface temperature 43C

    The MOA low surface temperature towel rail is recommended for use in care homes, hospitals, rented accommodation or anywhere that the general public may come in to direct contact with a heated towel rail. Turning on the MOA element will warm the towel radiator up to the pre-set temperature of approximately 43C. On the control panel the blue LED lights up to indicate the current (ON) status of the element. The element will automatically turn itself off until the temperature drops below 43C, and will continue to operate thermostatically.


    The MOA also has a timer function button, this will activate the 2 hour timer function and automatically turns itself off after 2 hours. The timer mode is indicated with a red LED light. Pressing the timer mode again will deactivate the timer function and revert back to the standard heating mode blue LED. Automatic


    The MOA also has an antifreeze function, as long as the element is connected to the mains supply the temperature sensor continues to control heating at medium temperature. This means that the antifreeze function remains active when the heater is turned off. As soon as the temperature around the sensor drops below 6ºC the MOA will switch itself on and prevent the heating medium from freezing!

  • Ideal for care homes or where low surface temperatures are essential
  • Stylish low surface temperature thermostatic element pre-set to 43C!
  • Antifreeze function protects against radiator temperature falling below 6ºC
  • Element can be left switched on permanently @ low cost heating!
  • Available widths: 350, 400, 450, 500, 600 & 750 mm
  • Available heights: 600, 700, 800, 900, 1000, 1200, 1400, 1600 & 1800 mm
  • Low standby power consumption
  • Double overheating protection
  • IPX5 suitable for zone two bathrooms
  • 2 hour timer function
  • Colour match power cable
  • Outputs: 200W, 400W and 800W
  • Water proof rating: IPX5 (zone 2)
  • BEAB Approved Mark
  • Low Voltage Directive (LVD)
  • Standard UK ½” BSP element fittings

Additional Information

SKUPLSTCS
Power (kW)No
Btu'sNo
BrandPrestige

 

CodeHeight (mm)Width (mm)Pipe Centres (mm)Element (W)Tube Size (mm)
ZTK0006401-12101560040035520025
ZTK0006451-12101560045040520025
ZTK0006501-12101560050045520025
ZTK0006601-12101560060055520025
ZTK00069451-12101569145040520025

 

CodeHeight (mm)Width (mm)Pipe Centres (mm)Element (W)Tube Size (mm)
ZTK0008401-12101580040035520025
ZTK0008451-12101580045040520025
ZTK0008501-12101580050045520025
ZTK0008601-12101580060055520025

 

CodeHeight (mm)Width (mm)Pipe Centres (mm)Element (W)Tube Size (mm)
ZTK0012401-121015120040035520025
ZTK0012451-121015120045040520025
ZTK0012501-121015120050045520025
ZTK0012601-121015120060055520025

 

CodeHeight (mm)Width (mm)Pipe Centres (mm)Element (W)Tube Size (mm)
ZTK0014401-121016140040035540025
ZTK0014451-121016140045040540025
ZTK0014501-121016140050045540025
ZTK0014601-121016140060055540025

 

CodeHeight (mm)Width (mm)Pipe Centres (mm)Element (W)Tube Size (mm)
ZTK0016401-121016160040035540025
ZTK0016451-121016160045040540025
ZTK0016501-121016160050045540025
ZTK0016601-121016160060050580025

 

    What is the warranty of the radiator?

      15 Years on the radiator and 2 years on the electrical element.

    What is the timer function used for?

      Basically the LST element has an ON / OFF button and 2hr heating button. If the user wants to turn the towel rail OFF after using it in the morning for example they can use the 2 hour timer function which will continue to heat - dry towels for 2 hrs and then it will turn itself off automatically, indicated by the red LED light. After 2hrs the element will then revert to antifreeze mode if the 2 hr timer function is activated

    Can the element be tampered with to cause harm?

      The elements cant be tampered with to cause any harm, the element has 2 functions - its either on indicated by blue LED light or its on the 2hr timer mode indicated by red LED light. Pressing the ON/OFF button again will cancel the timer mode function and revert back to 43C heating.

        What if the element is turned off accidentally at the controls?

          Providing there is power to the element, (hard wired) as soon as the temperature around the sensor falls below 6 °C the element will switch on automatically preventing the heating medium inside the radiator from freezing! Activation of ANTIFREEZE function is indicated by slow blue LED flashes every 3 seconds.
View FileCare and Maintenance    Size: (181.28 KB)
View File600 Straight Chrome CAD    Size: (101.81 KB)
View File700 Straight Chrome CAD    Size: (102.72 KB)
View File800 Straight Chrome CAD    Size: (103.66 KB)
View File900 Straight Chrome CAD    Size: (103.66 KB)
View File1000 Straight Chrome CAD    Size: (104.41 KB)
View File1200 Straight Chrome CAD    Size: (105.54 KB)
View File1400 Straight Chrome CAD    Size: (106.07 KB)
View File1600 Straight Chrome CAD    Size: (103.01 KB)
View File1800 Straight Chrome CAD    Size: (103.91 KB)
View FileLST Manual 2017    Size: (468.49 KB)

Write Your Own Review

Only registered users can write reviews. Please, log in or register

Customer Reviews